Oil-free magnetic bearings
SMARDT magnetic-bearing technology removes the oil system from the chiller compressor arrangement.
Chillers
Central plant chillers, engineered together with pumps, cooling towers and plant controls.
Product enquiries 0972 033 330
Overview
APC supplies SMARDT oil-free magnetic-bearing and CLIVET water-cooled chillers for central cooling plants. Equipment selection connects to plant design, controls, commissioning and long-term service for data centers, pharmaceutical facilities and manufacturing.
SMARDT magnetic-bearing technology removes the oil system from the chiller compressor arrangement.
CPECS / iCPECS coordinates the chiller, water pumps and cooling towers as one operating system.
APC plans equipment replacement around the site constraints and operating requirements.
Commissioning, performance verification and operator training support the transition to operation.
Technical specifications
Published project references are identified separately from the model-specific data confirmed with your proposal.
| Type | Water-cooled; SMARDT oil-free magnetic bearing / CLIVET oil-lubricated |
|---|---|
| Reference compressor count | 4 on the BAT 520 RT unit |
| Refrigerant | Available on request |
| Catalog capacity range | Available on request |
| BAT commissioning COP | 7.4–9.6 at the documented part-load conditions |
|---|---|
| BAT chilled water | Inlet / return approximately 13–14 °C; outlet / supply approximately 11 °C |
| BAT condenser water | Approximately 26–33 °C across the recorded tests |
| Reference unit capacities | 110–625 RT per unit in the published installations; not a catalog range |
| Plant controls | CPECS / iCPECS plant optimization; project-specific selection |
|---|---|
| Supporting equipment | Pumps, HVAC MCC panels and BMS / FCMS control cabinets |
| Selected communication protocol | Available on request |
| Handover | Testing, commissioning and operator training |
|---|---|
| After-sales scope and service terms | Available on request |
Exact model, capacity and efficiency are selected per project. Send us your load profile for a sized proposal.
Discuss your load profileSystem integration
APC coordinates the supporting systems around your selected plant and project scope.
APC power and control panels built to the applicable IEC / Japanese project standards.
Coordinated control of chillers, pumps and cooling towers for plant energy optimization.
Control cabinets connect HVAC equipment to the building and facility control strategy.
Energy logging supports the review of plant operation and measured performance.
Reference installations
| Client | Application | Location | Capacity | Reference |
|---|---|---|---|---|
| Viettel Group | Data center | Hanoi | 600 RT × 2 | View project |
| BAT – Vinataba | Manufacturing retrofit | Dong Nai | 520 RT | View project |
| Hau Giang Pharmaceutical | Pharmaceutical factory | Hau Giang | 625 RT × 4 | APC source |
| Hau Giang Pharmaceutical | Pharmaceutical factory | Can Tho | 110 RT | View project |
| Rang Dong Plastic | Manufacturing | Long An | 300 RT × 2 | View project |
| Phong Phu Corporation | Textile factory | — | 523 RT | View project |
| Vemedim Phase 3 | Animal health factory | Hau Giang | 420 RT × 2 | APC source |
| Equatorial Hotel | Hospitality retrofit | Ho Chi Minh City | 450 RT | View project |
Across APC’s customer network
Downloads & references
Request a quote
Share your operating requirements. APC can confirm a suitable model, capacity and scope.
Related products

Heat Rejection
MESAN cooling towers with VAF filtration and coordinated plant controls.
View product
Chillers
CLIVET cooling for sites without cooling towers or with limited process water.
View product
Air Side
Air handling equipment selected around the airflow, treatment and control requirements.
View product